DNA-RNA Extraction Controls
MeridianSmartSearch
Use Meridian's Smart Search to find your product by entering a disease, product name, or catalog number in the below:
Product Filters
Products (7)
Name | Specimen Type | Application | Catalog | Order a Sample | Sizes | Description | Wet(Liquid) | Air-Dryable | Dryable | Glycerol-Free | Lyo-Ready | Concentration | High Concentration | Detail | Safety Data Sheet | COA/Test Release | User Guide | Product Handling Guide | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VLP-RNA Extraction Control Red | VLP Extraction Controls | RT-qPCR | MDX068 | Order a Sample | Available in 1 mL (~1×10^4 copies/µL) and 20 mL (~1×10^4 copies/µL) aliquots | An Internal Control RNA sequence, with no known homology to any organism, encapsidated in a virus-like particle and a VLP Detection Mix containing primers and probe to the internal control RNA sequence. |
Yes | Yes | Air-Dryable,Lyo-Ready | YesYes | Yes | 10^4 copies/µL | No | View Details | Safety Data Sheet | COA/Test Release | ||||
VLP-RNA Extraction Control Orange | VLP Extraction Controls | RT-qPCR | MDX069 | Order a Sample | Available in 1 mL (~1×10^4 copies/µL) and 20 mL (~1×10^4 copies/µL) aliquots | An Internal Control RNA sequence, with no known homology to any organism, encapsidated in a virus-like particle and a VLP Detection Mix containing primers and probe to the internal control RNA sequence. |
Yes | Yes | Air-Dryable,Lyo-Ready | YesYes | Yes | 10^4 copies/µL | No | View Details | Safety Data Sheet | COA/Test Release | ||||
VLP-RNA Extraction Control | VLP Extraction Controls | RT-qPCR | MDX071 | Order a Sample | Custom | An internal custom control RNA sequence, encapsidated in a virus-like particle. |
Yes | Yes | Air-Dryable,Lyo-Ready | YesYes | Yes | Custom | No | View Details | Safety Data Sheet | |||||
qPCR Extraction Control Red | Extraction Controls | qPCR | MDX026 | Order a Sample | Available in 10 mL (2,000 Rxns) aliquots | Control used to monitor the success of a qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample DNA. |
Yes | No | No | NoNo | No | 25x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | |||
qPCR Extraction Control Orange | Extraction Controls | qPCR | MDX027 | Order a Sample | Available in 10 mL (2,000 Rxns) aliquots | Control used to monitor the success of a qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample DNA. |
Yes | No | No | NoNo | No | 25x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | |||
RT-qPCR Extraction Control Red | Extraction Controls | RT-qPCR | MDX028 | Order a Sample | Available in 1 mL (500 Rxns) aliquots | Control used to monitor the success of an RT-qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample RNA. |
Yes | No | No | NoNo | No | 25x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide | |||
RT-qPCR Extraction Control Orange | Extraction Controls | RT-qPCR | MDX029 | Order a Sample | Available in 1 mL (500 Rxns) aliquots | Control used to monitor the success of an RT-qPCR assay from lysis/extraction to amplification and reduces the chance of obtaining false negative results from the sample RNA. |
Yes | No | No | NoNo | No | 25x | No | View Details | Safety Data Sheet | COA/Test Release | Product Handling Guide |
Not seeing what you’re looking for? Inquire about a new product
Catalogs & Brochures
Meridian Air Dryable Direct StoolqPCR Extraction Controls
Meridian Air Dryable Direct StoolVLP-RNA Extraction Control
Meridian Air Dryable Direct StoolVLP Extraction Control Custom Project
Get In Touch With A Specialist
Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!